The balloon manufacturer did not have an adequate process to verify the accuracy of the temperature recorded during production inflation tests.
The updated production test procedure includes a more comprehensive test for balloons with modified deflation systems, which includes redundant temperature sensors and guidance on correct sensor installation. In addition, all standard balloons no longer use temperature sensors for the test, being replaced by a specific weight to be lifted which will ensure greater consistency in the internal envelope pressure during the test independent of ambient conditions. These changes adequately address the safety issue.
To address the safety issue, Kubicek Balloons advised the ATSB of the following safety actions implemented in May 2023:
Kubicek Balloons is asked to provide advice during the directly involved party process of any other significant safety actions it has undertaken related to this occurrence.