Safety Recommendation

The Australian Transport Safety Bureau recommends that the Civil
Aviation Safety Authority consider advising Australian helicopter
operators, involved in water-bombing in support of fire fighting
operations, of the need to review the type of fire-buckets used to
ensure that they comply with the bucket manufacturer's guidance for
use on helicopter types and to ensure that they are appropriately
maintained.

Organisation Response
Date Received
Organisation
Civil Aviation Safety Authority
Response Status
Response Text

The following response was received from the Civil Aviation
Safety Authority on 6 February 2004:



In response to the Bureau's recommendation, CASA is currently
preparing a letter to helicopter operators in which the following
issues will be highlighted:



* Ensure the bucket is compatible with the helicopter for which it
is to be used;

* Ensure compatibility of the ring or the device to connect the
hook and the bucket;

* Ensure the operators maintenance program encapsulates the bucket
and it's supporting equipment; and

* Remind operators of their obligation to ensure that any aircraft
component fitted from time to time to the aircraft is also
maintained correctly in accordance with Civil Aviation Regulations
(CAR) 39 and 41.



CASA will seek comment on the content of the letter from major
operators, including CHC, prior to its distribution.

Date Received
Organisation
Civil Aviation Safety Authority
Response Status
Response Text

CASA issued a letter (see below) to operators on 4 August 2004. With the impending fire season, CASA sees a benefit in re-issuing the letter and is arranging for it to be updated and sent.

Notwithstanding that the ATSB was apparently advised in 2004 that the Flight Safety Australia article did not cover the action item in R20030221, CASA believes the article does actually cover the issues raised.

ATSB Note:

The Flight Safety Australia article, CASA issues safety advice for helicopter firefighting referred to in the CASA response text is available on page 10 of the July-August 2004 issue of the magazine and can be found at www.casa.gov.au

The text of the CASA letter referred to is included below:

Subject: Rotorcraft In Fire Suppression Operations Using Underslung Equipment.

Dear Sir or Madam,

Using rotorcraft in aerial application operations, including fighting bush fires using a fabric "bucket" or similar equipment suspended from the cargo hook has become common practice.

In response to the ATSB investigation into a recent near-fatal accident involving helicopter fire bombing operations using an underslung bucket, and with regard to the forthcoming fire-fighting season, CASA takes this opportunity to make the following recommendations to all rotorcraft operators who engage in similar aerial application operations.

Ensure that:

  1. The bucket is compatible with the helicopter with which it will be used. Bucket manufacturers should provide guidance with regard to the range of rotorcraft suitable for use with a particular model bucket. Ensure the applicable model bucket is deployed with the recommended helicopter type and model, and that the recommended bucket and helicopter combination is maintained throughout operations.
  2. The cargo hook is appropriately maintained. CIVIL AVIATION REGULATIONS 1988, REG 39 (1) applicable to Class A helicopters, and CAR 41 (2) applicable to Class B helicopters, require that either a System of Maintenance or a maintenance schedule include provision for carrying out maintenance to all aircraft components from time to time included in, or fitted to, the helicopter. This includes the cargo hook. Operators therefore should have procedures in place to ensure the cargo hook assembly, plugs, wiring and the attaching structure is inspected at appropriate intervals while fitted to the helicopter.
  3. The hook release mechanism is fully operational. The hook release systems, both manual, and electrical, should be functionally tested before commencing operations each day, and each time the hook assembly is fitted to a helicopter. The hook should be electrically "armed" during all sling operations, ready for quick release in an emergency.
  4. The ring or device used to connect the bucket or load to the hook is compatible with the hook. A review of accidents involving loads slung from the hook, reveals that the use of the incorrect size and shape of the ring that links any load attached to the hook could have potentially disastrous results. Problems include an unintended release, (dynamic roll-out) where the strop or ring collapses the hook "keeper" or "mouse" and the load detaches from a closed hook. Another problem encountered has been the load not releasing when intended, even though the hook opens, due to the ring jamming on the hook assembly.

CASA strongly recommends that all appropriate actions be completed, and the necessary procedures put in place before fire fighting operations commence to ensure that this service, so greatly appreciated by the community, is conducted safely.