Investigation number
200103238
Occurrence date
Location
Perth, Aero.
State
Western Australia
Report release date
Report status
Final
Investigation type
Occurrence Investigation
Investigation status
Completed
Aviation occurrence category
Fumes
Occurrence class
Incident
Highest injury level
None

During the take-off roll, the cabin manager of the BAe 146 aircraft became aware of a smoky, burning smell coming from an air vent in the region of her crew seat at the forward (L1) exit door. Initially there was a mild odour. That was followed by the rapid onset of strong fumes for a short period after which the fumes dissipated quickly. The event was of 2-3 minutes duration.

The cabin manager felt overwhelmed by the fumes and was on the verge of passing out when her colleagues became aware of the situation and provided her with portable oxygen. After approximately 10 minutes of using oxygen, the cabin manager felt well enough to attempt a resumption of her duties but was unable to continue due to the effect of the fumes exposure.

The cabin manager, who had ten years of operational experience on the BAe 146, spent the duration of the flight seated at the rear of the aircraft; breathing portable oxygen for most of that time. The cabin manager reported that when she was not using oxygen she felt unwell, she had difficulty in thinking clearly and she found it difficult to coordinate her thoughts with her actions. No other members of the crew or any of the passengers reported being affected by the fumes.

Upon arrival in Kununurra, engineering inspections were performed on the aircraft and further action was deferred in accordance with the Civil Aviation Safety Authority airworthiness directive AD/BAe146/086. That airworthiness directive required certain actions to be performed whenever a cabin air quality problem was identified, which was suspected of being associated with oil contamination of the air supply from the air conditioning packs. Subsequent engineering inspections revealed that the cause of the oil contamination was a worn number one bearing seal in the number 3 engine. The engine was replaced and no further fumes were evident during following flights.

The cabin manager sought medical treatment and tests in Kununurra on the day of the incident and in Perth on the following day. Although she was eventually cleared to return to work, symptoms of anxiety, impaired judgement, and light-headedness remained with her for in excess of one week. Of note was the result of a blood test that revealed she had been exposed to a higher than normal level of carbon monoxide (CO). When inhaled, CO combines with the haemoglobin, the blood's oxygen-carrying molecule, to form carboxyhaemoglobin (COHb). Once in that state, the haemoglobin is unable to carry oxygen. Thus, the blood's ability to carry oxygen to body tissues, including vital organs such as the heart and brain, is inhibited.

CO is the product of incomplete combustion of carbonaceous material. It is found in varying amounts in the smoke and fumes from burning aircraft engine fuels and lubricants. The gas itself is colourless, odourless, and tasteless but is usually mixed with other gases and fumes that can be detected by sight or smell. Individuals that have been exposed to CO should be removed from the exposure and administered 100 percent oxygen through a tight fitting mask until all symptoms have been resolved. If blood testing for measurement of COHb level is required, the samples should be drawn as soon as possible after the exposure, as COHb has a short half-life in the body of 4-5 hours. If an individual is administered 100 percent oxygen, the half-life is reduced to 40 to 80 minutes.

The same aircraft was the subject of a pilot report three days prior to the cabin manager's experience, in which an oil-like smell was evident in the cockpit but not in the cabin. The event was of short duration and occurred just after take-off, when the source of air supply was changed from the Auxiliary Power Unit (APU) to the engines. Inspection by maintenance engineers of the engines, APU, and air-conditioning system revealed no signs of contamination and the defect was cleared.

Evidence from previous incidents of air system contamination on this type of aircraft has indicated that fumes were associated with engine or APU oil contamination of the air conditioning system. The BAe146 is similar to many aircraft in that the supply of cabin air originates in the aircraft's engines. Air is bled from the final stage of the engine's high-pressure compressor just prior to the combustion chamber. The air destined for the cabin then passes through a catalytic converter in order to clean the air of any oil contaminants. Catalytic converters operate at maximum efficiency under highly specific conditions of temperature and contaminant to air ratio. The air is then passed through a heat exchanger and then through one of two air conditioning packs before entering the cabin. During normal operation bleed air from engines one and two is fed to pack one, which in turn supplies conditioned air to the flight deck and cabin. Bleed air from engines three and four is fed to pack two, which normally only supplies air to the cabin. Additionally, bleed air from the APU is used by either pack during the take-off and landing phases or when air conditioning is required on the ground.

Aircraft Details
Manufacturer
British Aerospace PLC
Model
BAe 146
Registration
VH-JJU
Serial number
E2116
Operation type
Air Transport High Capacity
Sector
Jet
Departure point
Perth, WA
Destination
Kununurra, WA
Damage
Nil