Investigation number
200105060
Occurrence date
Location
Brisbane, Aero.
Report release date
Report status
Final
Investigation type
Occurrence Investigation
Investigation status
Completed
Aviation occurrence type
Hydraulic
Occurrence category
Incident
Highest injury level
None
Local safety action
As a result of the investigation, the following safety actions
were carried out:
The operator issued a memo to its engineering staff highlighting
the need for:
- extra vigilance when inspecting the rear fuselage area;
and - all hydraulic fluid leaks to be treated as potential total
hydraulic failure and to be reported to maintenance watch.
The engine buildup unit contractor issued Service Bulletin, Rohr
SB R715.29-001 on 9 November 2001, that provided instructions to
install a pulsation attenuator to each engine driven hydraulic
pump.
The airframe manufacturer issued an All Operators Letter (AOL)
717-048 on the 18 January 2002, recommending that operators install
the hydraulic pump outlet attenuator (via Rohr Service Bulletin
R715.29-001) to minimize hydraulic system vibrations.
Aircraft Details
Manufacturer
The Boeing Company
Model
717
Registration
VH-IMD
Serial number
55055
Operation type
Air Transport High Capacity
Departure point
Sydney, NSW
Departure time
2030 hours EST
Destination
Coolangatta, QLD
Damage
Minor