Maintenance of sanders
Date issue released
Safety Issue Description

Maintenance of the VLocity sander units did not include testing of sand discharge flow rates (or some other process) to confirm performance. Without performance checks over time, deficiencies could not be identified and addressed.

Issue number
RO-2020-007-SI-04
Issue Status
Closed – Adequately addressed
Transport Function
Rail: Passenger - regional
Issue Owner
V/Line
Mode of Transport
Rail
Proactive action
Action number
RO-2020-007-PSA-03
Organisation
V/Line
Action Status
Closed
Action description

V/Line has advised the ATSB that it has developed a sand flow test procedure that details testing methodology, including a minimum and maximum sand flow rate. This sand flow test has been added to the VLocity servicing schedule.